| Place of Origin: | China |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W201691123005 |
| Minimum Order Quantity: | 1set |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates ; wooden pallet and wooden box |
| Delivery Time: | 0-60 days after deposit received |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
| Place of Origin | China | Brand Name | CEC TANKS |
|---|---|---|---|
| Certification | ISO 9001:2008, AWWA D103 , OSHA , BSCI | Model Number | W201691123005 |
| Steel Plates Thickness: | 3mm To 12mm , Depends On The Tank Structure | Corrosion Integrity: | Excellent |
| Chemical Resistance: | Excellent | Capacity: | 20 M3 To 18,000 M3 |
| Service Life: | ≥30 Years | Permeability: | Gas / Liquid Impermeable |
| Highlight: | makeup water tank for data center cooling,fusion bonded epoxy makeup tank,side-stream treatment makeup water tank |
||
A data-center cooling loop loses water to evaporation, drift, and bleed-off, and the makeup water tank is the buffer that replaces it so the towers never run dry during a supply interruption. The engineering is not just 'a tank of water' - it is water chemistry, conductivity control, and side-stream treatment sized to the cooling duty. This article explains how a makeup buffer supports data-center cooling and what to specify so the loop stays stable and compliant.
A makeup water tank for data-center cooling should be specified by makeup demand (evaporation + drift + bleed-off), water chemistry (conductivity and scaling control), and a lining matched to the treated water (GFS fired at 820-930 C or FBE, holiday-tested to 1500 V, 8.8-grade bolts). Pair the tank with side-stream filtration and a bleed-off strategy so the loop does not concentrate solids, and size the buffer to ride through the longest credible supply gap. Center Enamel has no data-center project in this library; we cite a real chilled/process-water delivery, the Italy Sardinia tank (30,549 m3, 2025), as proof of building large coated chilled/process-water tanks, not as a data-center delivery.
Cooling towers lose water three ways - evaporation (the largest, tied to heat removed), drift (entrained droplets), and bleed-off (intentional blowdown to control concentration). The makeup tank must replace all three, so size it to the tower duty and the local supply reliability, not to a generic fraction of cooling load.
Evaporation, drift, bleed-off - the tank replaces all three.
As water cycles through the tower, dissolved solids concentrate, raising conductivity and scaling risk, so a bleed-off and treatment strategy keeps the loop inside its limits. The makeup tank should be lined for the treated water chemistry, and the connection protected against backflow per EN 1717 so the buffer cannot contaminate the supply.
Concentration control is the loop's lifeline.
Side-stream filtration removes suspended solids so the concentrated loop stays clean, and it pairs naturally with the makeup buffer: clean makeup in, controlled bleed-off out. A sealed, screened tank design resists biofilm and stagnation, which matters where the buffer may sit between draws.
Filter the loop; seal the buffer.
Size the buffer to the makeup demand and the longest credible supply interruption - for a data center, even a short dry tower can trip IT cooling - and site it for fast refill and easy inspection. A bolted GFS or FBE tank with panel-ID traceability supports future expansion if the campus grows.
Buffer the gap; the IT load cannot wait.
We have no data-center project in this library. Our Italy Sardinia chilled/process-water tank (30,549 m3, 2025) is a real coated chilled/process-water delivery cited as analogous proof of building large, code-aware cooling/process buffers, not a data-center delivery. The cooling-loop guidance above reflects documented GFS/FBE parameters, not a specific data-center contract.
Every figure reflects documented coated-tank parameters, and the data-center application remains analogous and is not claimed.
Reference check |
Action |
Red flag |
Makeup demand |
Duty-based |
Generic % |
Chemistry |
Bleed-off plan |
None |
Buffer |
Ride the gap |
Undersized |
DC claim |
Analogous only |
Fabricated |
It replaces water lost from cooling towers and chilled-water loops to evaporation, drift, and bleed-off so the towers never run dry.
Size it to the cooling-tower makeup demand (evaporation plus drift plus bleed-off) and the longest credible supply interruption, not a generic fraction of load.
Blowdown controls the concentration of dissolved solids in the loop; without it, conductivity and scaling rise and the tower fouls.
GFS (fired at 820-930 C) or FBE, holiday-tested to 1500 V, matched to the treated water chemistry, with NSF-61 where the water is potable-adjacent.
A stream drawn from the loop, filtered, and returned to remove suspended solids so the concentrated cooling water stays clean.
Not in our project library. We cite our real Sardinia chilled/process-water tank as analogous capability, not a data-center delivery.
Use an air gap or reduced-pressure zone per EN 1717 so the makeup buffer cannot backflow into the supply.
Yes - a sealed, screened design resists biofilm and stagnation, which matters when the buffer sits between draws.
A bolted GFS or FBE design with panel-ID traceability supports adding a ring later as cooling demand increases.
A makeup water tank for data-center cooling is the buffer that replaces tower losses - evaporation, drift, and bleed-off - and it must be specified by makeup demand and water chemistry, not by volume alone. Pair a GFS or FBE, holiday-tested, chemically matched tank with side-stream filtration and a bleed-off strategy, protect the supply with EN 1717 backflow prevention, and size the buffer to ride through the longest credible supply gap because the IT load cannot wait for a dry tower. Center Enamel's real Sardinia chilled/process-water tank (30,549 m3, 2025) shows we build large, code-aware cooling/process buffers; the data-center application is analogous and not claimed. Specify the chemistry and the gap first, and the loop stays stable instead of scaling up. A buffer that is sized to the duty and lined for the treated water, with a documented bleed-off and side-stream plan, is what keeps a data-center cooling loop from the scaling and fouling that quietly erode chiller efficiency. Where the campus adds cooling capacity year by year, a bolted design with panel-ID traceability lets the buffer grow with the load instead of being replaced.
Suggested CTA: If you are specifying a makeup water tank for data-center cooling, send us the tower duty, water chemistry, and supply reliability and we will return a chemistry-matched, EN 1090-compliant buffer design.