| Place of Origin: | China |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W |
| Minimum Order Quantity: | 1set |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates ; wooden pallet and wooden |
| Delivery Time: | 10-30 days after deposit received |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
| Place of Origin | China | Brand Name | CEC TANKS |
|---|---|---|---|
| Certification | ISO 9001:2008, AWWA D103 , OSHA , BSCI | Model Number | W |
| Tank Material: | Glass Fused To Steel | Foundation: | Concrete Or Glass Fused Steel |
| Steel Plates Thickness: | 3mm To 12mm , Depends On The Tank Structure | Size Of Panel: | 2.4M * 1.2M |
| Easy To Clean: | Smooth, Glossy, Inert, Anti-adhesion | Permeability: | Gas / Liquid Impermeable |
| Highlight: | Data center water tank Italy,Potable-contact industrial water tanks,Water-authority compliant water tanks |
||
A data center water tank in Italy is a storage vessel that holds makeup water, process top-up or an isolated fire reserve for an Italian colocation or compute site, and the specification is shaped by water-authority permitting and the potable-contact rules that apply to the site. Italy is a growing southern-European data-center market where a large, steady makeup demand meets basin authorities that control abstraction and discharge. Center Enamel supplies Glass-Fused-to-Steel, Fusion-Bonded Epoxy and stainless bolted tanks engineered for water duty, with more than 30,000 installed tank projects across 100-plus countries. This article sets out the compliance-first specification baseline an Italian data-center project should work from.
A single water tank on an Italian data-center site can serve three distinct duties: evaporated-cooling makeup, closed-loop or process top-up, and a fire reserve held under separate control. Treating them as one volume is the most common specification error, because the potable-contact and backflow requirements differ between a makeup line and a fire line. The correct approach assigns a defined volume and a documented isolation point to each duty, then sizes the shell for the sum while keeping the quality boundaries explicit. Where water stress limits abstraction, the makeup balance becomes a permitting question as much as a tank-sizing one.
For a data-center water tank in Italy, abstraction and discharge are governed by Italian water law and the competent basin or regional authority, and a permit can be required depending on the source and volume. Materials in contact with water intended for human consumption are commonly specified to EU framework Regulation 1935/2004 and, where a potable claim is made, to a recognised scheme such as NSF/ANSI 61 or an approved member-state equivalent. The shell falls under the national building framework and UNI-EN technical conditions. The Vigili del Fuoco sets the fire reserve and access conditions. Confirm each with the authority having jurisdiction at concept stage.
A thermal store, chilled-water buffer, data-center water reservoir or fire reserve sits idle or cycles slowly for most of its life, so the internal finish and the shell discipline matter more than the nameplate rating. Glass-Fused-to-Steel panels are fired at 820-930 degrees C to give a smooth inert skin at 0.25-0.45 mm thickness, adhesion above 3,450 N/cm2 and 100 percent 1,500 V DC spark testing per panel. Fusion-Bonded Epoxy bolted tanks (Resicoat R4-ES interior 180-280 micrometres, Interpon D2015 exterior 150-250 micrometres, adhesion above 16 MPa) and hot-dip galvanized bolted tanks cover specified or cost-sensitive duties. Stainless 304 or 316 is chosen where the fluid is low-mineral or a factory-fabricated vessel is preferred. The caveat is that lining choice follows fluid chemistry and code duty, so the specifier should confirm pH, chloride load and pressure class rather than assume one construction fits every duty.
Sizing starts from the real duty calculation - thermal charge/discharge profile, chilled-water temperature swing, makeup and process balance, or fire hydraulic demand - not from a catalogue number. The coating thickness of 0.25-0.45 mm for GFS or 180-280 micrometres for FBE, a 30-50 year tank lifecycle, the NSF/ANSI 61 or WRAS potable-contact option where relevant, and the local freeze or seismic margin then set the shell, roof and appurtenances. Every figure below is checked against the applicable standard and the authority having jurisdiction in the destination country.
Design parameter |
Typical value or range |
Why it matters |
Makeup peak flow |
Site-specific m3/h |
Sets drawdown and refill rate |
Separated duty volumes |
Makeup + process + fire |
Prevents quality cross-contamination |
Potable-contact option |
NSF/ANSI 61 / EU 1935/2004 |
Required where water feeds human-use system |
Backflow protection |
Isolated, verified connections |
Protects the public supply |
Coating thickness |
0.25-0.45 mm enamel / 180-280 um FBE |
Idle-water surface integrity |
Adhesion |
above 3,450 N/cm2 (GFS) |
Lining integrity on drawdown |
Spark test |
1,500 V DC per panel |
Holiday verification |
Design lifecycle |
30-50 years |
Standby-plus-cyclic water duty |
The figure below is a REAL Center Enamel delivery cited here as manufacturing-capability evidence for the tank type discussed, NOT as a claimed thermal-energy-storage, chilled-water, data-center water or fire-water delivery in the named country. Center Enamel's verified project record (case_library.csv) holds no dedicated TES, chilled-water, data-center-water or Belgium/Poland/Italy/Sweden/Finland fire-water tank project for this specific duty; where a real in-country tank exists it is cited as the closest analogue, never as the named application. Poland, Finland and Belgium have no in-country project entries in the available source at all. This reference demonstrates the ability to engineer large coated and bolted water tanks for demanding duty, not a claim about this specific application or geography. Where the source did not record a diameter or height, the field reads Not Provided and is never estimated.
Project |
Country |
Tank type |
Volume |
Year |
Relevance |
Brazil potable-water tank |
Brazil |
GFS bolted tank |
1 tank, 6,076 m3 |
2022 |
Real potable-water tank (capability, not an Italy data-center water project) |
Issue a duty schedule that names each stored volume, its water quality, its refill and drawdown rates and its isolation point, then require the supplier to demonstrate the lining system, coating thickness, adhesion and spark-test record. Reject a proposal that quotes only a geometric volume with no link to the makeup balance or the fire demand. Because an Italian basin authority governs abstraction, the winning specification lets the operator prove compliance from the tank documentation alone and accommodates a drier summer water balance.
It can hold evaporated-cooling makeup, closed-loop top-up water and an isolated fire reserve - each with its own quality and isolation requirements.
The competent basin or regional authority under Italian water law; a permit can depend on the source, volume and local water stress.
Where the stored water feeds a system used for human consumption, materials are commonly specified to EU 1935/2004 and a recognised scheme such as NSF/ANSI 61 or an equivalent approval.
Only with separately assigned volumes and documented isolation and backflow protection; the water-quality and control requirements differ.
GFS enamel for inert standby water, FBE or galvanized for specified or cost-sensitive duty, and stainless where the fluid is low-mineral.
From the makeup peak flow and drawdown/refill balance plus the separately calculated fire reserve - not from a generic rule of thumb.
Thickness (0.25-0.45 mm for GFS or 180-280 micrometres for FBE), adhesion above 3,450 N/cm2 for GFS and 100 percent 1,500 V DC spark testing per panel.
Yes - a drier summer balance can limit abstraction and make the makeup reserve larger and the refill strategy more important.
About 30 days ex-works for a 1,000-10,000 m3 vessel, with bolted erection on site in weeks.
A 30-50 year shell lifecycle is expected; the lining drives the maintenance interval under cyclic water duty.
Yes - the lining should be warranted separately because water chemistry and drawdown cycles stress the coating more than the shell.
A verified single shell of 20,000 m3 was delivered in 2016, setting the upper bound for one bolted tank.
No - it is a real potable-water tank cited as capability evidence, not a claimed Italy data-center project.
Yes - GFS, FBE and stainless bolted tanks with the coating documentation and permit-ready records an authority review requires.
Because makeup, process and fire water have different quality and backflow requirements, and merging them makes compliance to the water authority and fire service hard to demonstrate.
A data-center water tank in Italy is specified around water-authority permits, potable-contact rules and a clean separation of makeup, process and fire volumes. Size it from the real water balance and demand lining evidence.
Suggested CTA: Issue a per-duty water schedule and require documentable lining evidence before ordering an Italy data-center water tank.