| Place of Origin: | China |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W20160504018 |
| Minimum Order Quantity: | 1set |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates ; wooden pallet and wooden box |
| Delivery Time: | 0-60 days after deposit received |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
| Place of Origin | China | Brand Name | CEC TANKS |
|---|---|---|---|
| Certification | ISO 9001:2008, AWWA D103 , OSHA , BSCI | Model Number | W20160504018 |
| Coating Thickness: | 0.25mm~0.40mm , Two Layer Of Coating Internal And External | Tank Material: | Glass Fused To Steel |
| Corrosion Integrity: | Excellent | Chemical Resistance: | Excellent |
| Highlight: | stratified chilled water tank,buffer tank peak shaving,industrial water storage tank |
||
A chilled-water storage tank in Sweden is a stratified vessel that stores cold water produced off-peak and releases it during the peak, letting a plant shave electrical demand and defer chiller capacity. Swedish data centers, hospitals and commercial buildings use chilled-water storage to reduce peak grid load, and the tank turns cheap night-time cooling into a dispatchable reserve. Center Enamel supplies Glass-Fused-to-Steel, Fusion-Bonded Epoxy and stainless bolted tanks engineered for chilled-water duty, with more than 30,000 installed tank projects across 100-plus countries. This article sets out the duty-led specification baseline a Swedish chilled-water project should work from.
A stratified chilled-water tank holds cold water at the bottom and returns warmer water at the top. Charging runs chillers at night or during low-cost hours to fill the tank; discharging serves the building or process load during the peak without starting additional chillers. The economic value is the avoided peak chiller capacity and demand charge, so the tank is sized from the peak-hour cooling deficit and the number of hours to be covered. In Sweden the free-cooling season can extend the charge window, but an outdoor tank needs insulation and freeze protection so the stored cold is not lost to the climate.
For a chilled-water storage tank in Sweden the shell falls under the Planning and Building Act (PBL) and Boverket's building regulations, with EN 28765 commonly specified for a glass-fused-to-steel construction. A closed chiller loop is not normally a potable system, so the internal specification is a process-contact one unless a human-use connection exists; where one does, Swedish drinking-water and EU 1935/2004 requirements apply. Water treatment and blowdown discharge fall under the Swedish Environmental Code. The local räddningstjänst sets access and separation. Confirm these interface points early, and give the cold-climate insulation and freeze detail the same attention as the tank volume.
A thermal store, chilled-water buffer, data-center water reservoir or fire reserve sits idle or cycles slowly for most of its life, so the internal finish and the shell discipline matter more than the nameplate rating. Glass-Fused-to-Steel panels are fired at 820-930 degrees C to give a smooth inert skin at 0.25-0.45 mm thickness, adhesion above 3,450 N/cm2 and 100 percent 1,500 V DC spark testing per panel. Fusion-Bonded Epoxy bolted tanks (Resicoat R4-ES interior 180-280 micrometres, Interpon D2015 exterior 150-250 micrometres, adhesion above 16 MPa) and hot-dip galvanized bolted tanks cover specified or cost-sensitive duties. Stainless 304 or 316 is chosen where the fluid is low-mineral or a factory-fabricated vessel is preferred. The caveat is that lining choice follows fluid chemistry and code duty, so the specifier should confirm pH, chloride load and pressure class rather than assume one construction fits every duty.
Sizing starts from the real duty calculation - thermal charge/discharge profile, chilled-water temperature swing, makeup and process balance, or fire hydraulic demand - not from a catalogue number. The coating thickness of 0.25-0.45 mm for GFS or 180-280 micrometres for FBE, a 30-50 year tank lifecycle, the NSF/ANSI 61 or WRAS potable-contact option where relevant, and the local freeze or seismic margin then set the shell, roof and appurtenances. Every figure below is checked against the applicable standard and the authority having jurisdiction in the destination country.
Design parameter |
Typical value or range |
Why it matters |
Peak cooling deficit |
Site-specific kW or MW |
Sets the required volume |
Hours of peak covered |
Shift duration |
Derives usable capacity |
Charge temperature |
Supply chilled-water setpoint |
Defines the cold reservoir |
Insulation / freeze margin |
Site-specific cold-climate value |
Protects stored cold |
Coating thickness |
0.25-0.45 mm enamel / 180-280 um FBE |
Idle-surface integrity |
Adhesion |
above 3,450 N/cm2 (GFS) |
Lining integrity on cycling |
Spark test |
1,500 V DC per panel |
Holiday verification |
Design lifecycle |
30-50 years |
Standby-plus-cyclic cold duty |
The figure below is a REAL Center Enamel delivery cited here as manufacturing-capability evidence for the tank type discussed, NOT as a claimed thermal-energy-storage, chilled-water, data-center water or fire-water delivery in the named country. Center Enamel's verified project record (case_library.csv) holds no dedicated TES, chilled-water, data-center-water or Belgium/Poland/Italy/Sweden/Finland fire-water tank project for this specific duty; where a real in-country tank exists it is cited as the closest analogue, never as the named application. Poland, Finland and Belgium have no in-country project entries in the available source at all. This reference demonstrates the ability to engineer large coated and bolted water tanks for demanding duty, not a claim about this specific application or geography. Where the source did not record a diameter or height, the field reads Not Provided and is never estimated.
Project |
Country |
Tank type |
Volume |
Year |
Relevance |
Russia stainless industrial-water tanks |
Russia |
Stainless steel tank (304/316L) |
2 tanks, 519 m3 total |
2024 |
Real cold-climate water tank (capability, not a Sweden chilled store) |
Issue a duty schedule that states the peak cooling deficit, the hours of peak to cover, the supply temperature and the achievable off-peak charge window, then require the supplier to show how volume, diffuser layout, insulation and freeze protection deliver that duty. Reject a quote based on geometric volume alone: a store with a mixed thermocline delivers warm water long before it is empty. Because Sweden applies general building and environmental instruments, anchor the specification in those instruments and keep the lining records ready for review.
It stores cold water made off-peak and releases it at the demand peak, shaving grid load and deferring chiller capacity.
From the peak-hour cooling deficit and the hours to cover, then checked against the temperature swing and stratification quality.
The Planning and Building Act (PBL) and Boverket regulations, with EN 28765 commonly specified for a glass-fused-to-steel shell.
Usually not - a closed chiller loop is a process-contact system; potable rules apply only if a human-use connection exists.
GFS enamel for inert idle water, FBE for a specified duty, or stainless where the fluid is low-mineral and a fabricated vessel is preferred.
A sharp thermocline keeps stored cold usable; a mixed store delivers warm water long before the geometric volume is empty.
Thickness (0.25-0.45 mm for GFS or 180-280 micrometres for FBE), adhesion above 3,450 N/cm2 for GFS and 100 percent 1,500 V DC spark testing per panel.
Yes - insulation and freeze protection are needed so an outdoor store does not lose its charge to the Swedish climate.
About 30 days ex-works for a 1,000-10,000 m3 vessel, with bolted erection on site in weeks.
A 30-50 year shell lifecycle is expected, with lining and diffuser internals driving maintenance.
Yes - the lining should be warranted separately because cycling stresses the coating more than the shell.
A verified single shell of 20,000 m3 was delivered in 2016, setting the upper bound for one bolted tank.
No - it is a real cold-climate stainless water tank cited as capability evidence, not a claimed Sweden chilled store.
The source lists a Swedish GFS biogas tank, but no chilled-water store; that project is used in the TES article, not here.
Free cooling can extend the charge window in cold months but does not remove the need to size the charge and discharge duty explicitly.
A chilled-water storage tank in Sweden is sized from the peak deficit and cover hours, with usable capacity set by stratification and a cold-climate insulation and freeze strategy. Demand lining evidence and anchor the spec in PBL and Boverket rules.
Suggested CTA: State peak deficit, cover hours and supply temperature, and require a stratification and freeze strategy before ordering a Sweden chilled-water tank.