| Place of Origin: | China |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W20171218003 |
| Minimum Order Quantity: | 1set |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates ; wooden pallet and wooden box |
| Delivery Time: | 10-30 days after deposit received |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
| Place of Origin | China | Brand Name | CEC TANKS |
|---|---|---|---|
| Certification | ISO 9001:2008, AWWA D103 , OSHA , BSCI | Model Number | W20171218003 |
| Permeability: | Gas / Liquid Impermeable | Elastic: | Same As Steel Sheet ,around 500KN /mm |
| Tank Body Color: | Dark Green / Can Be Customized | Coating Thickness: | 0.25mm~0.40mm , Two Layer Of Coating Internal And External |
| Foundation: | Concrete Or Glass Fused Steel | Roof Available: | Glass Fused Steel Roof , Membrane Roof, Aluminum Roof , GRP Roof |
| Highlight: | stratified chilled water storage tank,cold buffer industrial water tank,peak shaving water storage tank |
||
A chilled water storage tank in Germany is a stratified cold buffer that stores off-peak cooling and releases it during peak demand, cutting chiller capacity and energy cost under the German efficiency framework. The tank must demonstrate low standby loss, clean stratification and a documented insulation spec to satisfy plan review. Center Enamel supplies Glass-Fused-to-Steel, Fusion-Bonded Epoxy and stainless bolted tanks engineered for chilled-water standby, with more than 30,000 installed tank projects across 100-plus countries. The right cold tank is sized from the cooling load profile and the peak-shaving window, not from a generic size.
A stratified chilled-water tank keeps a warm top and a cold bottom so the chiller charges at night and the building or process draws cold water by day. German projects value the standby-loss documentation and the insulation spec under the efficiency rules, and the tank must keep the thermocline clean. The drawings must reference DIN/EN and the local building authority so the store is verifiable.
A tank that supports a data-center cooling loop, thermal store or fire reserve sits idle for most of its life, so the internal finish and the shell discipline decide reliability more than the nameplate rating. Glass-Fused-to-Steel panels are fired at 820-930 °C to give a smooth inert skin at 0.25-0.45 mm thickness, adhesion above 3,450 N/cm2 and 100 percent 1,500 V DC spark testing per panel. Fusion-Bonded Epoxy bolted tanks (Resicoat R4-ES interior 180-280 micrometres, Interpon D2015 exterior 150-250 micrometres, adhesion above 16 MPa) and hot-dip galvanized bolted tanks cover specified or cost-sensitive duties. Stainless 304 or 316 is chosen where the fluid is low-mineral or a factory-fabricated pressure vessel is preferred, and ASME BPVC Section VIII governs a vessel that exceeds the local pressure-equipment threshold. A caveat applies: the right lining depends on the fluid chemistry and the code duty, so the engineer should confirm pH, halide load and pressure class rather than assume one construction fits every duty.
Sizing starts from the actual duty calculation - loop volume and temperature swing, thermal charge/discharge profile, cooling-makeup balance or fire hydraulic demand - not a catalogue number. The coating thickness of 0.25-0.45 mm for GFS or 180-280 micrometres for FBE, the tank lifecycle of 30-50 years, the NSF/ANSI 61 or WRAS potable-contact option and the freeze or tropical duty margin then set the shell, roof and appurtenances. Every figure below is confirmed against the applicable standard and the local authority having jurisdiction.
Design parameter |
Typical value or range |
Why it matters |
Cooling load profile |
Daily peak shape |
Drives volume |
Peak-shaving window |
Hours of offset |
Sets usable volume |
Supply-return glide |
Chilled-water band |
Stratification target |
Standby loss |
Insulation spec |
German efficiency rules |
Usable volume |
Volume between levels |
Normal-to-lowest level |
Coating thickness |
0.25-0.45 mm enamel |
Idle-surface integrity |
Adhesion |
above 3,450 N/cm2 |
Lining failure resistance |
Spark test |
1,500 V DC per panel |
100 percent holiday check |
The figure below is a REAL Center Enamel delivery used here as manufacturing-capability evidence for the tank type discussed, NOT as a claimed data-center cooling, thermal-energy-storage, chilled-water, immersion, expansion or Germany/Ireland/Netherlands project. Center Enamel's verified project record (case_library.csv) holds no data-center cooling-loop, TES, chilled-water, immersion, expansion-vessel or DE/IE/NL tank delivery, so this reference demonstrates the ability to engineer large coated, stainless and bolted water tanks for demanding duty, not a claim about this specific application or geography. Where the source did not record a diameter or height, the field reads Not Provided and is never estimated.
Project |
Country |
Tank type |
Volume |
Year |
Relevance |
Chile desalination |
Chile |
Epoxy-coated bolted tank |
3,289 x2 m3 |
2024 |
Real export tank (capability, not DE chilled) |
Require the usable volume tied to the cooling load profile and the peak-shaving window, the insulation and standby-loss specification, and the coating documentation. Reject any proposal that quotes only a geometric volume without the stratification and loss calculation.
It stores off-peak cooling as a stratified cold buffer and releases it during peak demand to cut chiller capacity and energy cost.
A chilled-water tank is a sensible cold store; TES is the broader term covering hot, cold and latent storage.
From the cooling load profile and the peak-shaving window, with the usable volume between the normal and lowest effective levels.
A documented insulation and stratification loss, so the tank must prove low standby loss under the efficiency framework.
GFS enamel for inert standby, FBE or galvanized for specified duty, stainless where the fluid is low-mineral.
Thickness (0.25-0.45 mm GFS or 180-280 micrometres FBE), adhesion above 3,450 N/cm2 and 1,500 V DC spark testing per panel.
Center Enamel supplies GFS, FBE and stainless bolted tanks engineered to EN 28765 and ISO 9001, delivered to 100-plus countries; German standards are applied per project.
About 30 days ex-works for a 1,000-10,000 m3 vessel, with on-site erection in weeks.
A 30-50 year shell lifecycle, with the lining driving the maintenance interval under cyclic duty.
Yes - the lining should be warranted because cyclic chilled-water duty stresses the coating more than the steel.
A verified single shell of 20,000 m3 delivered in 2016.
Yes - as a stratified cold buffer that shifts cooling peak and supports liquid-cooling loops.
Oversizing wastes capital and still leaves the load exposed to peaks; a cold tank shifts demand far more cheaply.
Yes - a clean thermocline is what makes the stored cold usable; a mixed tank loses most of its value.
Only if it exceeds the local pressure-equipment threshold; most atmospheric cold buffers fall outside ASME.
A chilled water storage tank in Germany provides a stratified cold buffer that shifts cooling peak and cuts chiller capacity, and its value comes from the usable volume, the standby-loss spec and the clean thermocline. The coating evidence and insulation documentation decide whether the store performs, and those numbers must come from the cooling load profile rather than a generic size.
Suggested CTA: Specify a German chilled-water tank on load profile, standby-loss spec and documented coating evidence before purchase.