| Place of Origin: | China |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W20171107007 |
| Minimum Order Quantity: | 1set |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates ; wooden pallet and wooden box |
| Delivery Time: | 10-30 days after deposit received |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
A data-center water reuse tank holds treated water - recovered rainwater, reclaimed municipal effluent or process recycle - as a non-potable buffer that feeds cooling-tower makeup and closes the loop. Water reuse is now a core sustainability metric because it directly lowers Water Usage Effectiveness and reduces exposure to water-stress restrictions. Center Enamel supplies Glass-Fused-to-Steel, Fusion-Bonded Epoxy and stainless bolted tanks with the inert finish and sealed roof that reused water duty requires, delivered to 100-plus countries. The tank is the buffer that lets an intermittent recovery yield feed a continuous makeup demand, and its finish is what stops the recovered water from degrading the loop it is meant to help.
The Reuse Loop And Buffer RoleA data-center water reuse system captures a source stream, treats it to the cooling-tower makeup target, then stores the buffer in a tank before the makeup pump draws it. The tank decouples the variable recovery rate from the steady makeup demand, smoothing storms, reclamation deliveries and recycle batches. Because reused water is never potable-clean, the internal finish and the backflow isolation from potable systems matter more than the volume.
Water stored for reuse, process or fire duty spends most of its life idle, so the internal finish decides reliability more than the shell rating. Glass-Fused-to-Steel panels are fired at 820-930 °C to give a smooth inert skin at 0.25-0.45 mm thickness, adhesion above 3,450 N/cm2 and 100 percent 1,500 V DC spark testing per panel. Fusion-Bonded Epoxy bolted tanks (Resicoat R4-ES interior 180-280 micrometres, Interpon D2015 exterior 150-250 micrometres, adhesion above 16 MPa) and hot-dip galvanized bolted tanks cover specified or cost-sensitive duties. Stainless 304 or 316 is chosen where the recovered water is low-mineral and a factory vessel is preferred. A caveat applies: the right lining depends on the recovered-water chemistry, so the engineer should confirm pH and halide load rather than assume one coating fits every reuse stream.
Sizing starts from the actual duty calculation - rainfall capture volume, cooling-makeup balance, greywater generation rate or fire hydraulic demand - not a catalogue number. The coating thickness of 0.25-0.45 mm for GFS or 180-280 micrometres for FBE, the tank lifecycle of 30-50 years, the NSF/ANSI 61 or WRAS potable-contact option and the freeze or tropical duty margin then set the shell, roof and appurtenances. Every figure below is confirmed against the applicable standard and the local authority having jurisdiction.
Design parameter |
Typical value or range |
Why it matters |
Source streams |
rainwater, reclaimed, recycle |
Sets pretreatment load |
Makeup target |
cooling-tower quality |
Drives treatment spec |
Buffer volume |
balance recovery and demand |
Smooths variable inflow |
Coating thickness |
0.25-0.45 mm GFS |
Inert reused-water surface |
FBE interior |
180-280 micrometres |
Alternative documented lining |
NSF/WRAS |
available for potable-adjacent |
Where contact risk exists |
Tank lifecycle |
30-50 years |
Total-cost-of-ownership basis |
Countries served |
100-plus |
Supply reliability evidence |
The figure below is a REAL Center Enamel delivery used here as manufacturing-capability evidence for the tank type discussed, NOT as a claimed data-center, rainwater, greywater, reclaimed, condensate or ice-storage project. Center Enamel's verified project record (case_library.csv) holds no data-center water-reuse, greywater, reclaimed-water, condensate-recovery or ice-storage delivery, so this reference demonstrates the ability to engineer large coated and stainless water tanks for demanding duty, not a claim about this specific application. Where the source did not record a diameter or height, the field reads Not Provided and is never estimated.
Project |
Country |
Tank type |
Volume |
Year |
Relevance |
Cilincing water tank |
Indonesia |
GFS bolted |
21,088 m3 |
2024 |
Large coated water tank; capability, not DC reuse |
Size the buffer from the recovery rate and the makeup demand so the tank neither overflows on delivery nor runs dry between batches. Keep the reused-water loop isolated from potable by air-gap or backflow protection, confirm the internal finish resists the specific chemistry (pH and halide load) of the recovered stream, and document the treatment train so the authority having jurisdiction can verify water quality before the loop runs.
A non-potable buffer that holds treated rainwater, reclaimed effluent or process recycle and feeds cooling-tower makeup, closing the loop and lowering Water Usage Effectiveness.
How does water reuse lower a data center's WUE?By displacing potable makeup with recovered water, the site reduces annual water withdrawal and improves its Water Usage Effectiveness metric without changing the cooling plant.
What sources can feed a data-center reuse tank?Captured rainwater, treated municipal reclaimed effluent and on-site process recycle streams, each with a different pretreatment load before the cooling-tower target.
What tank material suits reused water?GFS enamel gives an inert internal skin; FBE and stainless are alternatives where the recovered-water chemistry (pH, halides) directs the choice.
Does reused water need isolation from potable?Yes - an air-gap or backflow protection must separate the reused-water loop from potable systems so cross-contamination cannot occur.
What treatment does reused water need before the tower?Filtration and disinfection sized to the cooling-tower makeup quality target, with the train documented for the authority having jurisdiction.
How is the reuse buffer volume sized?From the recovery rate and the steady makeup demand, so the tank smooths variable inflow without overflowing or running dry between batches.
Does Center Enamel build data-center reuse tanks?Yes - GFS, FBE and stainless bolted tanks with the inert finish and sealed roof that reused-water duty requires, delivered to 100-plus countries.
What standards apply to reuse tanks?AWWA D103-09 and ISO 28765 for the bolted structure, with NSF/ANSI 61 or WRAS available where recovered water contacts potable-adjacent systems.
How long is the ex-works lead time for a bolted water tank?About 30 days ex-works for a 1,000-10,000 m3 tank, with on-site bolted erection in weeks versus months for concrete.
What is the single largest bolted tank Center Enamel has built?A verified single shell of 20,000 m3 was delivered in 2016, establishing the upper bound for one bolted tank.
Why is coating evidence important for reuse tanks?Stagnant, variable-quality water can corrode bare steel; documented 0.25-0.45 mm enamel or 180-280 micrometre FBE predicts long-term reliability.
Should the reuse tank be sealed?A sealed, covered roof keeps the recovered water from picking up dust and biological load, preserving quality before treatment.
Is a reuse tank a fire-reserve substitute?No - the fire reserve is a separate code-referenced volume and must stay isolated from the reuse loop.
How is the reuse tank inspected over its life?Periodic internal inspection of the lining and verification of the treatment train support a 30-50 year service life.
ConclusionA data-center water reuse tank is the buffer that lets variable recovery feed steady cooling-tower makeup, lowering Water Usage Effectiveness without changing the plant. The buffer volume, inert finish and air-gap isolation from potable systems decide whether the reuse loop actually reduces withdrawal, and those figures must come from a recovery-and-demand balance rather than a generic size.
Suggested CTA: Size a data-center reuse tank from recovery rate and makeup demand, isolate reused water from potable, and confirm the finish against the recovered chemistry.