| Place of Origin: | China |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W |
| Minimum Order Quantity: | 1set |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates ; wooden pallet and wooden |
| Delivery Time: | 10-30 days after deposit received |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
Rapid urbanization, industrial expansion, and stricter environmental protection mandates place immense pressure on municipal authorities and environmental engineers. Managing the vast volume of domestic sewage, industrial wastewater run-off, and combined municipal discharge requires robust, highly reliable containment infrastructure. Traditional poured-in-place concrete basins and welded carbon steel tanks frequently fail prematurely under aggressive chemical attack, continuous mechanical wear, and biogenic hydrogen sulfide (H2S) exposure, resulting in costly structural leaks and environmental hazards.
To establish a new performance benchmark for municipal sewage treatment and industrial wastewater management, industry leaders rely on Glass-Fused-to-Steel (GFS)—also known as glass-lined steel—bolted tanks. Engineered and manufactured by Shijiazhuang Zhengzhong Technology Co., Ltd. (Center Enamel), GFS industrial wastewater treatment tanks combine the high tensile strength and flexibility of structural steel with the exceptional chemical inertness of glass, delivering decades of maintenance-free service across primary, secondary, and tertiary treatment stages.
A comprehensive municipal wastewater treatment plant (WWTP) relies on specialized tank configurations to handle different stages of water purification:
Flow Equalization (EQ) Basins: Municipal and industrial inflows fluctuate dramatically throughout the day. EQ tanks buffer these hydraulic and organic shock loads, ensuring a stable, controlled feed rate for downstream biological processes.
Primary Sedimentation & Clarification Tanks: Utilizing calm gravity separation, these tanks remove heavy suspended solids, grit, and undissolved organic particles before biological treatment begins.
Secondary Biological Aeration & CSTR Reactors: Serving as the biological heart of the plant, these tanks house activated sludge or microbial cultures that break down dissolved organic pollutants under aerobic or anaerobic conditions.
Sludge Thickening & Digestion Tanks: Concentrating and stabilizing sludge byproducts, requiring absolute leak-proof integrity and complete resistance to biogenic corrosive gases.
Center Enamel combines cutting-edge material science with precision modular engineering to address the severe demands of municipal environmental projects:
High-Temperature Thermal Fusion: Specialized glass enamel frit is applied to high-strength structural titanium-rich steel plates and fired in industrial furnaces between 820°C and 930°C. The resulting molecular fusion creates an inorganic glaze layer that permanently bonds the glass to the steel substrate.
Total Immunity to Chemical and Microbial Attack: The smooth, non-porous glass surface (Mohs hardness of 6.0) completely resists industrial acids, alkalis, high-chloride municipal sewage, and microbial-induced corrosion (MIC), preventing bio-fouling and scaling.
Rapid Modular Bolted Construction: Prefabricated under strict factory quality controls, GFS panels are bolted together rapidly on-site using specialized structural sealants and high-tensile hardware, eliminating weather-dependent civil curing delays.
| Evaluation Metric | Center Enamel GFS Wastewater Tank | Cast-in-Place Concrete Basin | Traditional Welded Carbon Steel Tank |
|---|---|---|---|
| Corrosion & Chemical Defense | Superior (Inert glass coating blocks industrial acids, sulfides, and biological attack) | Moderate (Vulnerable to concrete carbonation, sulfate attack, and liquid seepage) | Low (Dependent on field-applied epoxy coatings that pit, blister, and peel) |
| Installation Velocity | Fast (Prefabricated modular panels bolted rapidly on-site with zero curing delays) | Very Slow (Months of civil formwork, pouring, and multi-week curing phases) | Moderate (Requires heavy field plate rolling, welding, and radiograph testing) |
| Lifecycle Maintenance Cost | Minimal (Smooth, anti-adhesion glass surface eliminates interior repainting) | High (Requires frequent structural crack sealing, leak injection, and patching) | High (Continuous maintenance overhead to prevent rust-through and structural failure) |
| Scalability & Relocation | High (Modular bolted design allows effortless height/diameter expansion or relocation) | None (Permanent civil asset; impossible to expand without major demolition) | Limited (Destructive cutting and field welding required to modify capacity) |
Engineering Assurance: All GFS industrial wastewater and municipal sewage tanks manufactured by Center Enamel comply strictly with internationally recognized quality standards, including ISO 28765, AWWA D103-09, ISO 9001, and NSF/ANSI 61, and undergo 100% high-voltage holiday spark testing (>1500V) prior to dispatch.
A: GFS tanks offer superior resistance against aggressive wastewater chemicals, hydrogen sulfide gas, and biological corrosion without requiring ongoing maintenance. Unlike concrete, which is porous and susceptible to cracking or structural degradation under shifting ground loads, GFS tanks feature a factory-engineered modular bolted design that installs rapidly and eliminates civil curing delays.
A: The non-porous, glossy glass interior prevents sludge adhesion, bio-fouling, and mineral scaling. This minimizes maintenance downtime, keeps cleaning effortless, and ensures smooth hydraulic performance throughout primary, secondary, and tertiary treatment phases.
A: Yes. Center Enamel provides specialized enamel formulations capable of handling standard grade pH ranges (3 to 11) as well as heavy-duty industrial applications with extreme pH environments ranging from 1 to 14, ensuring absolute structural safety across diverse municipal-industrial mixed streams.
A: Yes. Because GFS tanks are built from standardized modular bolted panels, municipal operators can easily dismantle upper ring sections, add new panels to increase height or diameter, and scale up total containment volume with minimal disruption to ongoing plant operations.