| Place of Origin: | China |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W |
| Minimum Order Quantity: | 1set |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates ; wooden pallet and wooden |
| Delivery Time: | 10-30 days after deposit received |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
| Place of Origin | China | Brand Name | CEC TANKS |
|---|---|---|---|
| Certification | ISO 9001:2008, AWWA D103 , OSHA , BSCI | Model Number | W |
| Feature: | Eco-friendly, Durability | Tank Material: | Glass Fused To Steel |
| Chemical Resistance: | Excellent | Size Of Panel: | 2.4M * 1.2M |
| Easy To Clean: | Smooth, Glossy, Inert, Anti-adhesion | Capactiy Available: | 20 M3 To 20,000 M3 |
| Highlight: | EN 12845 water storage tank,sprinkler compliance water tank,industrial water storage tank |
||
A chilled-water storage tank in Spain is a stratified vessel that stores cold water produced off-peak and releases it during the hot afternoon peak, letting a plant shave electrical demand and defer chiller capacity. Spain's cooling season and high solar generation make afternoon peak shaving attractive, and the tank is the component that turns cheap midday or night-time cooling into a dispatchable reserve. Center Enamel supplies Glass-Fused-to-Steel, Fusion-Bonded Epoxy and stainless bolted tanks engineered for chilled-water duty, with more than 30,000 installed tank projects across 100-plus countries. This article sets out the duty-led specification baseline a Spanish chilled-water project should work from.
A stratified chilled-water tank holds cold water at the bottom and returns warmer water at the top. Charging runs chillers at night or during low-cost solar hours to fill the tank; discharging serves the building or process load during the peak without starting additional chillers. The economic value is the avoided peak chiller capacity and demand charge, so the tank is sized from the peak-hour cooling deficit and the number of hours to be covered, not from a rule of thumb.
For a chilled-water storage tank in Spain the applicable framework is the UNE-EN tank and water-contact family together with the CTE building code and the local fire authority, plus EU energy-efficiency policy where the storage supports a regulated efficiency measure. A closed chilled-water loop usually needs a process-contact specification rather than a potable approval, but the makeup connection must be backflow-protected and documented. Confirm the structural loading, the fire separation and the energy-measurement point with the authority having jurisdiction before the tank is ordered.
A thermal store, chilled-water buffer, data-center water reservoir or fire reserve sits idle or cycles slowly for most of its life, so the internal finish and the shell discipline matter more than the nameplate rating. Glass-Fused-to-Steel panels are fired at 820-930 degrees C to give a smooth inert skin at 0.25-0.45 mm thickness, adhesion above 3,450 N/cm2 and 100 percent 1,500 V DC spark testing per panel. Fusion-Bonded Epoxy bolted tanks (Resicoat R4-ES interior 180-280 micrometres, Interpon D2015 exterior 150-250 micrometres, adhesion above 16 MPa) and hot-dip galvanized bolted tanks cover specified or cost-sensitive duties. Stainless 304 or 316 is chosen where the fluid is low-mineral or a factory-fabricated vessel is preferred. The caveat is that lining choice follows fluid chemistry and code duty, so the specifier should confirm pH, chloride load and pressure class rather than assume one construction fits every duty.
Sizing starts from the real duty calculation - thermal charge/discharge profile, chilled-water temperature swing, makeup and process balance, or fire hydraulic demand - not from a catalogue number. The coating thickness of 0.25-0.45 mm for GFS or 180-280 micrometres for FBE, a 30-50 year tank lifecycle, the NSF/ANSI 61 or WRAS potable-contact option where relevant, and the local freeze or seismic margin then set the shell, roof and appurtenances. Every figure below is checked against the applicable standard and the authority having jurisdiction in the destination country.
Design parameter |
Typical value or range |
Why it matters |
Peak cooling deficit |
Site-specific kW or MW |
Sets the discharge duty |
Peak hours covered |
Hours per day |
Derives stored volume |
Supply/return temperature |
Chilled-water delta-T |
Defines usable cold |
Thermocline target |
Sharp interface |
Preserves usable volume |
Coating thickness |
0.25-0.45 mm enamel / 180-280 um FBE |
Idle-surface integrity |
Adhesion |
above 3,450 N/cm2 (GFS) |
Lining integrity on cycling |
Spark test |
1,500 V DC per panel |
Holiday verification |
Design lifecycle |
30-50 years |
Daily charge/discharge duty |
The figure below is a REAL Center Enamel delivery cited here as manufacturing-capability evidence for the tank type discussed, NOT as a claimed thermal-energy-storage, chilled-water, data-center water or fire-water delivery in the named country. Center Enamel's verified project record (case_library.csv) holds no dedicated TES, chilled-water, data-center-water or Netherlands/Spain/France/UK/Belgium fire-water tank project for this specific duty; where a real in-country tank exists it is cited as the closest analogue, never as the named application. This reference demonstrates the ability to engineer large coated, stainless and bolted water tanks for demanding duty, not a claim about this specific application or geography. Where the source did not record a diameter or height, the field reads Not Provided and is never estimated.
Project |
Country |
Tank type |
Volume |
Year |
Relevance |
Italy municipal-water GFS tank |
Italy |
GFS bolted tank |
198 m3 |
2025 |
Real European water tank (capability analogue, not a chilled store) |
Require a duty schedule with the peak-hour cooling deficit, the hours to be covered and the supply/return temperatures, then ask the supplier to show the volume and diffuser design that deliver that duty. Reject a bid that quotes a volume with no thermocline or inlet-stratification detail, because poor mixing can cut usable cold dramatically. Keep the lining evidence and the UNE-EN and CTE documentation ready for review, and define the metering approach if the tank supports an efficiency claim.
A stratified tank that stores cold water made off-peak and releases it during the hot afternoon peak, shaving electrical demand and deferring chiller capacity.
From the peak-hour cooling deficit and the number of peak hours to cover, checked against the supply/return temperature band - not from a generic factor.
A sharp thermocline keeps cold water separate from returning warm water, preserving the usable stored cold; poor mixing cuts effective capacity.
A closed chilled loop usually needs a process-contact specification, though the makeup connection must be backflow-protected and documented.
The UNE-EN tank and water-contact family, the CTE building code and local fire-service conditions, plus EU efficiency policy where the storage supports a measured measure.
GFS enamel for inert idle water, FBE for a specified duty, or stainless where the fluid is low-mineral and a fabricated vessel is preferred.
Thickness (0.25-0.45 mm for GFS or 180-280 micrometres for FBE), adhesion above 3,450 N/cm2 for GFS and 100 percent 1,500 V DC spark testing per panel.
Yes - charging during low-cost midday solar hours and discharging into the evening peak is a common peak-shaving pattern in Spain.
About 30 days ex-works for a 1,000-10,000 m3 vessel, with on-site bolted erection in weeks.
A 30-50 year shell lifecycle is expected, with the lining and diffuser internals driving the maintenance interval under daily cycling.
Yes - the lining should be warranted separately because daily thermal cycling stresses it more than the shell.
A verified single shell of 20,000 m3 was delivered in 2016, setting the upper bound for one bolted tank.
No - it is a real Italian water tank cited as a European manufacturing-capability analogue, not a claimed Spanish chilled-water delivery.
Yes - GFS, FBE and stainless bolted tanks sized from the real peak-shaving duty with documentable lining and construction records.
Because a tank covers the few peak hours with stored cold, letting the plant avoid buying chillers that would run only briefly at low utilisation.
A chilled-water storage tank in Spain is sized from the peak-hour cooling deficit and hours covered, with usable cold set by stratification rather than nameplate volume. Require a thermocline and diffuser strategy, documentable lining and an authority-ready compliance file.
Suggested CTA: State peak deficit, covered hours and supply/return temperatures, and require a stratification strategy before ordering a Spain chilled-water tank.