| Place of Origin: | CHINA |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W20180508003 |
| Minimum Order Quantity: | 1 SET |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates;wooden pallets and wooden box |
| Delivery Time: | 10-30 days after deposit received |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
| Place of Origin | CHINA | Brand Name | CEC TANKS |
|---|---|---|---|
| Certification | ISO 9001:2008, AWWA D103 , OSHA , BSCI | Model Number | W20180508003 |
| Coating Color: | Dark Green, Or Customizing Colors | Coating Thickness: | 0.25~0.40mm, Double Coating |
| Acid And Alkalinity Proof: | Standard Coating Suits For PH3 - PH11, Special Coating Suits For PH1 - PH14 | Adhesion: | 3,450N/cm |
| Hardness: | 6.0 Mohs | Holiday Test: | >1500V |
| Installation: | By Jacking Machine Or Steel Pole, Fast In Installation | Permeability: | Gas / Liquid Impermeable |
| Foundation: | Concrete Or Glass Fused Steel | Steel Grade: | ART 310 |
| Applications: | Water , Waste Water, Digester , Reactor , Grain , Sludge , Chemicals | Highlight: | Galvanized Steel Fire Water Tank,0.40mm Coating Thickness Fire Water Tank |
In industrial complexes, commercial developments, warehouses, and municipal zones, an uninterrupted, high-volume water supply is the absolute first line of defense against catastrophic fire events. When automated sprinkler systems or fire hydrants activate, every second counts, and the reliability of the water storage infrastructure dictates the outcome. Traditional concrete reservoirs and unlined carbon steel tanks frequently face long construction delays, seismic vulnerability, or premature internal corrosion.
To address these critical safety requirements, Shijiazhuang Zhengzhong Technology Co., Ltd. (Center Enamel) delivers engineered Galvanized Steel Fire Water Tanks. Combining high-tensile structural steel with advanced protective galvanizing and modular bolted design, these tanks provide a rapid, highly dependable, and code-compliant solution for private and municipal fire protection.
Fire suppression storage is subject to rigorous regulatory oversight. Unlike standard potable or process water tanks, fire protection reservoirs must meet strict guidelines to guarantee water availability under emergency conditions:
Guaranteed Usable Capacity: NFPA 22 mandates that a specified volume of water must be permanently dedicated exclusively to fire suppression, separated from daily utility drafts.
Structural Resilience Under Seismic and Wind Loads: Fire tanks must maintain structural integrity during extreme environmental stressors (such as high windstorms or earthquakes) to prevent structural collapse when water is most needed.
Corrosion Mitigation: Because fire water often sits stagnant for long periods, the interior walls must resist oxidation and scaling to prevent pipeline or sprinkler head clogs.
Center Enamel’s galvanized steel fire protection tanks are manufactured using precision-engineered modular panels that offer distinct performance benefits:
Superior Corrosion Resistance via Hot-Dip Galvanizing: The steel panels undergo a specialized hot-dip galvanizing process, coating the base metal in a tough, metallurgically bonded zinc layer that actively protects against atmospheric weathering, moisture, and rust.
Rapid Modular On-Site Assembly: Unlike cast-in-place concrete basins that require extensive formwork and multi-week curing delays, modular galvanized tanks are prefabricated in a factory and bolted rapidly on-site, significantly cutting project timelines.
Compliance with NFPA 22 and AWWA Standards: Every tank configuration is engineered to align with global benchmarks, incorporating essential fire protection appurtenances.
To ensure full operational compliance with NFPA 22, Center Enamel equips its galvanized fire water tanks with standard safety accessories:
Anti-Vortex Plate: Positioned above the discharge outlet with a compliant 90-degree elbow to prevent air from entering the pump suction line during high-flow operation.
Screened Roof Vents: Prevents internal vacuum pressures during rapid filling or draining while blocking debris and insects.
Access Manways and OSHA-Compliant Ladders: Secure, lockable roof hatches and caged or fall-arrest-equipped ladders for safe routine inspection and maintenance.
Water Level Indicators: Clear external gauges or low-level alarm integrations to allow facility operators to verify tank volume at a glance.
| Evaluation Metric | Center Enamel Galvanized Bolted Tank | Cast-in-Place Concrete Reservoir | Traditional Welded Steel Tank |
|---|---|---|---|
| Corrosion Protection | High (Hot-dip zinc galvanizing prevents rust and oxidation) | Moderate (Vulnerable to concrete carbonation and rebar rust spalling) | Low (Requires frequent external and internal field recoating) |
| Installation Speed | Fast (Prefabricated modular panels bolted rapidly on-site) | Very Slow (Months of formwork, pouring, and curing phases) | Moderate (Requires extensive field welding and NDT testing) |
| Seismic & Structural Reliability | High (Engineered to meet stringent ASCE 7 / NFPA 22 load criteria) | Moderate (Prone to structural cracking under severe ground movement) | High (Dependent on field weld quality and foundation design) |
| Maintenance Over Lifecycle | Minimal (Long-lasting zinc barrier reduces routine upkeep) | High (Requires frequent structural crack patching and sealing) | High (Continuous maintenance required to prevent rust-through) |
Engineering Assurance: Center Enamel provides comprehensive structural design calculation packages and quality verification to ensure every galvanized fire water tank meets or exceeds local AHJ (Authority Having Jurisdiction) submittal requirements for commercial and industrial fire safety.
A: Galvanized steel tanks offer an optimal balance of structural strength, exceptional corrosion resistance, and cost-effectiveness. Their modular bolted construction allows for fast deployment in both urban centers and remote industrial sites where concrete construction is impractical.
A: Yes. Our fire protection tanks are engineered to comply with major international standards—including NFPA 22 and AWWA D103—and feature required safety accessories such as anti-vortex plates, overflow lines, roof vents, and level indicators.
A: Because the steel panels are pre-engineered and fabricated in a climate-controlled factory, on-site installation is completed via mechanical bolting in a fraction of the time required to build a cast-in-place concrete reservoir.
A: Yes. For installations in regions experiencing sub-zero temperatures, the tanks can be customized with insulation packages and internal heating systems designed to maintain water temperatures above freezing in accordance with NFPA guidelines.