| Place of Origin: | CHINA |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W20180508003 |
| Minimum Order Quantity: | 1 SET |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates;wooden pallets and wooden box |
| Delivery Time: | 10-30 days after deposit received |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
For large-scale biogas operations, your storage infrastructure is not just a container—it is a critical chemical reactor. When processing organic waste, the internal environment is aggressive, characterized by high concentrations of hydrogen sulfide (H2S) and organic acids. Standard materials like carbon steel or concrete often suffer from Microbially Induced Corrosion (MIC), leading to costly leaks and structural decay.
A 500,000-gallon (approx. 1,900 m³) Glass-Fused-to-Steel (GFS) tank equipped with a Double Membrane Roof provides the ultimate combination of chemical resilience, structural integrity, and operational efficiency. This system is increasingly recognized by engineers and plant operators as the highest-performance, lowest-TCO (Total Cost of Ownership) solution for modern biogas facilities.
The glass-fused-to-steel process involves fusing silicate glass frit to high-strength steel plates at temperatures exceeding 820°C. This creates a molecular, inorganic bond that offers superior advantages over traditional field-welded tanks:
Immunity to Corrosion: Unlike epoxy coatings that can peel or blister, the GFS surface is thermally fused to the steel. It is chemically inert and immune to the acidic, sulfur-rich atmosphere of an anaerobic digester.
Non-Porous Surface: The smooth, glass-hard surface prevents the adhesion of biofilms and scum, ensuring efficient mixing and maximizing the bacterial activity essential for biogas yield.
Modular Construction: Our tanks are prefabricated in an ISO-certified factory and assembled on-site using a bolted, modular method. This guarantees consistent quality and significantly faster construction timelines compared to poured concrete.
For a 500,000-gallon digester, managing biogas volume is as important as the storage itself. A double membrane roof acts as an integrated gas holder, providing critical operational benefits:
Gas Volume Flexibility: The inner membrane expands and contracts based on the volume of biogas stored. This prevents over-pressurization and ensures a steady supply of gas to your CHP (Combined Heat and Power) units or upgrading systems.
Constant Pressure: The pressurized space between the inner and outer membranes (the air chamber) maintains a consistent discharge pressure, optimizing the efficiency of your gas utilization equipment.
Superior Sealing: By creating a hermetic seal over the entire tank, the double membrane system prevents methane leakage—supporting your environmental compliance and maximizing revenue from captured biogas.
Weather Resilience: The robust outer membrane is designed to withstand extreme wind, snow, and UV radiation, protecting the entire vessel for decades.
| Feature | GFS Tank + Double Membrane | Poured Concrete Tank | Welded Carbon Steel Tank |
| Corrosion Resistance | Superior (Inert Glass) | Low (Acid Susceptible) | Low (Needs Coating) |
| Installation Speed | Fast (Modular) | Slow (Weeks/Months) | Moderate |
| Gas Tightness | Excellent (Hermetic) | Moderate (Micro-cracking) | Moderate (Weld Defects) |
| Maintenance | Minimal | High (Crack Repair) | High (Recoating) |
| Lifespan | 30+ Years | 20–30 Years | 15–20 Years |
A: A 500,000-gallon (approx. 1,900 m³) capacity provides an optimal balance for mid-to-large-scale municipal wastewater plants, commercial food waste digesters, and agricultural manure processing facilities, offering sufficient retention time to maximize microbial breakdown while keeping the footprint manageable.
A: GFS tanks are thermally stable. The coating is engineered to handle the thermal cycling inherent in both mesophilic and thermophilic anaerobic digestion (typically 35°C to 55°C) without cracking or delaminating.
A: Yes. The bolted, modular nature of our GFS tanks allows for future scalability. If your feedstock availability increases, you can often add additional rings to the existing tank to increase volume, protecting your initial capital investment.
A: The membrane system is designed for durability, but it requires periodic inspection of the blower units (which maintain the air pressure) and the pressure-relief valves. Compared to the massive effort of sandblasting and repainting steel tanks, the maintenance requirement is minimal.
With over 30 years of experience, Center Enamel is a global leader in providing GFS tank and double-membrane roof systems. We deliver end-to-end support—from structural engineering and site-specific foundation calculations to professional, modular assembly.
Ready to start your 500,000-gallon biogas project? Contact our engineering team today to request a structural feasibility study and a technical proposal tailored to your feedstock and gas production goals.