| Place of Origin: | CHINA |
| Brand Name: | CEC TANKS |
| Certification: | ISO 9001:2008, AWWA D103 , OSHA , BSCI |
| Model Number: | W20180508003 |
| Minimum Order Quantity: | 1 SET |
| Price: | $5000~$20000 one set |
| Packaging Details: | PE poly-foam between each two steel plates;wooden pallets and wooden box |
| Delivery Time: | 10-30 days after deposit received |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 60 sets per month |
|
Detail Information |
|||
Industrial facilities, commercial warehouses, power plants, and large municipal developments require an uninterrupted, high-volume water supply to safeguard critical infrastructure and human life against catastrophic fire events. When insurance underwriters and fire safety authorities mandate massive reserve volumes—such as a standardized 200,000-gallon capacity—selecting the right containment infrastructure is vital. Traditional poured-in-place concrete basins are porous, vulnerable to micro-cracking, and subject to water seepage over time. Meanwhile, conventional field-welded steel tanks face progressive internal corrosion and require expensive, frequent repainting.
To establish an uncompromised standard for reliable fire protection, civil engineers and industrial safety planners increasingly specify 200,000 Gallon Bolted Steel Water Storage Tanks. Engineered and manufactured by Shijiazhuang Zhengzhong Technology Co., Ltd. (Center Enamel), these high-capacity modular reservoirs combine the structural tensile strength of industrial steel with advanced factory-applied coatings—such as Glass-Fused-to-Steel (GFS)—delivering decades of dependable, maintenance-free fire suppression readiness.
Fire suppression systems operate under extreme conditions, demanding absolute operational reliability:
Unfailing Immediate Availability: A 200,000-gallon tank must maintain its full volume 365 days a year, free from leakage, structural settling, or interior contamination that could clog sprinkler heads.
Strict Regulatory Compliance: Fire protection water reservoirs must strictly adhere to rigorous design codes, such as NFPA 22 (Standard for Water Tanks for Private Fire Protection) and AWWA D103, to satisfy local fire marshals and commercial insurers.
Resistance to Seismic and Environmental Loads: Massive volumes of water exert immense lateral forces; containment structures must withstand high wind loads, seismic activity, and severe freeze-thaw cycles without structural failure.
Center Enamel combines cutting-edge material science with precision modular engineering to deliver superior fire protection reservoirs:
NFPA 22 and AWWA D103 Compliance: Each 200,000-gallon system is custom-engineered to meet precise height-to-diameter ratios, providing exact usable water volumes while incorporating standard fire pump connections, vortex breakers, level indicators, and overflow configurations.
Factory-Controlled Precision Coating: Unlike field-welded tanks where coatings are applied outdoors under variable weather conditions, Center Enamel's bolted panels are factory-coated and thermally cured (including high-temperature GFS fusion at 820°C–930°C), ensuring flawless adhesion and maximum corrosion resistance.
Rapid Modular Bolted Construction: Prefabricated under strict ISO 9001 quality controls, modular tank panels ship flat to the job site and are bolted together rapidly on-site using high-tensile hardware, cutting installation timelines drastically compared to cast-in-place concrete.
| Evaluation Metric | Center Enamel Bolted Steel Fire Tank | Cast-in-Place Concrete Basin | Traditional Welded Steel Tank |
|---|---|---|---|
| Fire Code Compliance | Fully Certified (Engineered explicitly to meet NFPA 22 and AWWA D103 standards) | Requires custom engineering to meet ACI and local fire codes | Meets AWWA D100 standards |
| Corrosion & Rust Defense | Superior (Factory-fused glass or heavy-duty coatings eliminate internal rust) | Moderate (Vulnerable to concrete carbonation, sulfate attack, and liquid seepage) | Low (Dependent on field-applied epoxy coats that pit, blister, and peel over time) |
| Installation Velocity | Fast (Prefabricated modular panels bolted rapidly on-site with zero curing delays) | Very Slow (Months of civil formwork, pouring, and multi-week curing phases) | Moderate (Requires heavy field plate rolling, welding, and radiograph testing) |
| Lifecycle Maintenance Cost | Minimal (Smooth, durable interior surface eliminates frequent recoating overhead) | High (Requires frequent structural crack sealing, leak injection, and patching) | High (Continuous maintenance overhead to prevent rust-through and structural failure) |
Engineering Assurance: All 200,000-gallon fire protection storage tanks manufactured by Center Enamel comply strictly with internationally recognized quality benchmarks, including NFPA 22, AWWA D103-09, ISO 28765, and ISO 9001, and undergo rigorous quality inspections prior to factory dispatch.
A: A 200,000-gallon bolted steel tank provides the massive, reliable water volume required by large commercial facilities and industrial plants to satisfy NFPA guidelines. Bolted steel tanks offer superior structural strength, rapid on-site assembly, and a 30 to 50+ year service life without the risk of cracking inherent in concrete basins.
A: Yes. Center Enamel's fire protection water storage tanks are engineered in strict accordance with NFPA 22 (Standard for Water Tanks for Private Fire Protection) and AWWA D103 guidelines, ensuring full acceptance by local fire marshals and commercial insurance underwriters.
A: Center Enamel provides complete, turnkey fire tank packages that include standard internal and external ladders, safety cages, roof platforms, liquid level indicators, overflow pipes, drain valves, anti-vortex plates, and connection flanges sized specifically for industrial fire pump systems.
A: Because all structural panels are prefabricated and precision-drilled in a controlled factory environment, a 200,000-gallon bolted steel tank can typically be erected on-site in a fraction of the time required for cast-in-place concrete, eliminating lengthy civil curing delays and expediting project commissioning.